Slider

Flued Gas Space Heaters

PRS-250N, PRS-250L

Paloma Flued Gas space heaters offer fully automatic, thermostatically controlled heating. These high efficiency heaters provide rapid winter warmth and their coaxial flue system ensures room air remains fresh.

Gas Input: 23 (MJ/h)

Available Colours: Off White

  • Energy Efficiency Star Rating – 4.8 Stars
  • On/Off Operation – One touch electronic ignition
  • Dual Timers – can be set to operate automatically at two separate periods of the day (can be used as morning and evening timers). Timers can be set to operate with two timer periods, one timer period or none at all
  • Low Standby Power Usage – standby power consumption is just 1 Watt
  • Economy Mode – increases the efficiency of the heater. When Economy mode is activated the heater gradually reduces the room temperature by 1°C for every 30 minutes up to 2°C. This change in temperature is hardly noticeable
  • Preheat – the heater automatically operates up to one hour prior to the programmed starting time, so the room is at the required temperature when the programmed ON time is reached
  • Timer Override – allows you to manually override the preset program and operate the heater. The ‘Override’ button can be operated when the heater is in a Timer ON or Timer OFF period
  • Adjustable Room Temperature – when the heater is turned on, both the set temperature and room temperature are displayed on the screen. You can easily adjust the room temperature between 16°C & 26°C by using the arrows on the control panel.
  • Zero Indoor Emission Technology – Clean Indoor Air – These Paloma heaters are flued, which means the Paloma coaxial flue system expels flue gases to the outside so your room air remains fresh and is not compromised
  • Child Lock Mode – is available to prevent children interfering with the heater controls
  • Humidifier Tray – the heater has a humidifier tray located behind the lower front cover. The humidifier tray can be filled with water to raise the humidity level in the room, making it feel warmer and more comfortable
  • Vertical Louvre Adjustment – the louvres on the heater can be adjusted to direct air flow in the required direction by pushing the vertical section left or right
  • Standard Back Cover Spacer Kit – is supplied with the heater at no extra cost and is attached to the rear of the heater
  • Auto Timer Off Operation – the auto off timer is standard for all domestic & commercial models and can be activated so that the heater will automatically turn off after a preset time period. The heater has ten time settings – from 1 hour to 12 hours
  • Adjustable Legs – the heater can be leveled using the four adjustable legs supplied
  • Paloma designed gas valve – energy efficient seven stage modulating gas valve
  • Country of Manufacture – Japan
Model PRS-250
Application Domestic
Gas Input (MJ/h)  High NG/LPG 23
Gas Input (MJ/h)  Low NG/LPG 9
Heater Output (kW) 5.9
AS4553 Energy Star Rating 4.8
AS4553 Emission Star Rating 6
Max. Heating Capacity (MJ/h)  Very Cold 52
Cold 61
Cool 82
Mild 94
Electrical Power Cord Length (m) 1.5
Electrical Consumption (Watts)  High 58
Low 27
Standby 1
Humidifier Tray Capacity (L) 1
Colour Off White
Coaxial Flue Pipe Diameter (mm) 50 x 75
Thermostatic Control 16°C – 26°C
Dual Timers Yes
Auto Off Mode Yes
Preheat Function Yes
Economy Mode Yes
Override Function Yes
Child Lock Yes
Seven Stage Modulating Gas Valve Yes
Blocked Filter Indicator Yes
Lockable Control Panel No
24VAC Terminal Block No
Central Control Operation No
Dimensions: H x W x D (mm) 610 x 760 x 257
Packaged Weight (kg) 31

Order Codes

Natural Gas PRS-250N
LPG PRS-250L

* Refer to Heating Capacity Selection Table.

Description... Very Cold Cold Cool Mild
Max. Winter Daylight Temperatures... Less than 10°C 10°C – 12°C 13°C – 15°C 16°C – 20°C
Heater Models Approx. Heating Capacity (m²)
PRS-150 30 35 48 54
PRS-250 52 61 82 94
PRS-250C 52 61 82 94

Notes:
(1) The above table has been developed to serve as a guide only.
(2) Heating capacities are based on a maximum ceiling height of 2.7m.

Heat Selection Map

Direct Flue Kit

KITS REQUIRED QUANTITY PART #
Standard Direct Flue Kit
If wall thickness is less than 230 mm add Wall / Ceiling Plate Kit PFK5500
1 PFK1000

Sideways / Under Floor Flue Kit

KITS REQUIRED QUANTITY PART #
Sideways / Under Floor Flue Kit
Includes Standard Direct Flue Kit (PFK1000) & 90 Deg Bend
1
See note 5
PFK3000
Extra Wide Back Cover Kit 1 PWSK001
Coaxial Flue Pipe Kit See note 2 PFK4000
Coaxial 45º & 90° Bend Kit See note 3 PFK5100

Direct External Wall Flue Kit

KITS REQUIRED QUANTITY PART #
Standard Direct Flue Kit 1 PFK1000
Condensate Trap Kit 1 PFK5000
Coaxial Flue Pipe Kit See note 2 PFK4000
Coaxial 45º & 90° Bend Kit See note 3 PFK5100
Wall / Ceiling Plate Kit 1 PFK5500
Vertical Flue Cowl Kit 1 (A only) PFK5200

Vertical Internal Wall Flue Kit

KITS REQUIRED QUANTITY PART #
Vertical Internal Wall Flue Kit:
Includes Manifold Assembly with 90 Deg Bend & Condensate Trap, 4 x Coaxial Flue Pipe (PFK4000), Vertical Flue Cowl Kit (PFK5200), Wall Box Assembly Kit, Top Plate bracket, Drain Tube, Clips & Screws
1
See note 4
PFK2000
Coaxial Flue Pipe Kit See note 2 PFK4000
Coaxial 45º & 90° Bend Kit See note 3 PFK5100

Accessories

  • Extra Wide Back Cover Spacer Kit PWSK001 – for Sideways and Under Floor installations you will require a Paloma Wider Back Spacer kit. Use only with PFK3000. PWSK001 is suitable for Paloma models PRS-150, PRS-250 & PRS-250C.
  • Flue Terminal Guard Assembly Kit PFK5300 – a Stainless Steel Flue Terminal Guard is available to prevent the public or children coming in contact with the flue terminal.
  • Wall Plate Foam Seal Kit PFK5700 – for external sealing of Wall Plate on uneven weatherboard/cladding surfaces.
Notes:
1 Maximum flue length for all flue configurations is 9 metres total.
2 Coaxial flue pipe is 900 mm long – Order as many as required for installation.
3 Kit has 2 X 45° bends. Use 2 X 45º bends for each 90º bend. A maximum of two 90º bends is permissible for flue systems that terminate horizontally (direct extended, sideways, underfloor & horizontal external wall configurations). A maximum of three 90º bends is permissible for flue systems that terminate vertically (vertical external
wall & vertical in-wall configurations). Direct sideways configurations (as depicted) do not require any bends unless they are required to be offset.
4 PFK2000 – The use of a Vertical Internal Wall Flue kit will require an internal wall cavity depth of 90 mm (minimum).
5 Suitable for horizontal flue termination only. No vertical flue run is allowed. Condensation must drain to outside.

Stockist Locator

To locate one of our stockists, please enter your Australian postcode in the box below, choose a stockist type and then click search.

National Service

131 031

Sales Enquires

132 552

1300 729 725
1300 554 821